86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > VOLTAGE REGULATORS > KCR760 - Kato
KATO KCR760 Analogue AVR | Voltage Regulator | Jinjia Power

KATO KCR760 Analogue AVR - Analogue Automatic Voltage Regulator for KATO Alternators | OEM Replacement

KCR760

Status: IN STOCK, Same day shipping Worldwide available |

* Contact us for pricing and full specifications

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

SKUKCR760
BrandKATO
Model NumberKCR760
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited or PMG depending on variant
Sensing InputSingle-phase or three-phase sensing with voltage taps
Power InputFrom the main stator, 50 / 60 Hz
Output Voltage63-125 Vdc class
Continuous Field Current4-10 A class
Forcing CurrentShort-term forcing current available for load steps
Field Resistance (Min)Matched to the exciter field
Regulation Accuracy+/-1.0 per cent
Response TimeStandard analogue response
Frequency Range50 / 60 Hz
Under-Frequency ProtectionVolts-per-hertz roll-off
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via CT
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown, loss of sensing
Compatible AlternatorsKato Engineering alternators
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

What the KCR760 is. A Analogue Automatic Voltage Regulator built by KATO for brushless excitation systems. On paper the specification is a list; in service it is a set of limits. The current the board will hold indefinitely is 4-10 A class; the field resistance window it will drive without exceeding its output voltage is Matched to the exciter field; the tightest voltage band it can maintain is +/-1.0 per cent; and the ambient range in which all of that remains true is -40 to +60 degC.

Excitation architecture. Self-excited or PMG depending on variant. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. A voltage that is correct at no load and low at full load is almost never an accuracy problem. It is a current limit, a resistance problem or a cable problem.

Sensing. Single-phase or three-phase sensing with voltage taps. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.

Power stage and field drive. Power input From the main stator, 50 / 60 Hz, output 63-125 Vdc class. Field current rating 4-10 A class, forcing capability Short-term forcing current available for load steps, field resistance window Matched to the exciter field. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Never flash a field through the regulator. Disconnect the board, flash the field directly, then reconnect. Flashing through the AVR is how a working board becomes a failed board.

Accuracy and response. +/-1.0 per cent steady-state accuracy, Standard analogue response, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.

Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. An alternator that has been rewound needs its field resistance re-measured, because a rewind commonly moves it by ten to twenty per cent in either direction.

Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.

Protection built into the regulator. Over-excitation shutdown, loss of sensing. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

What it fits. Kato Engineering alternators. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Never flash a field through the regulator. Disconnect the board, flash the field directly, then reconnect. Flashing through the AVR is how a working board becomes a failed board.

Field notes on this model. Kato regulators are built for the alternator they are shipped with, so the model number is tied to the machine frame. On a replacement order the alternator nameplate data, meaning kVA, voltage and field resistance, is what determines the correct board, not the regulator part number alone.

Standby versus prime power. A standby set runs a few hundred hours a year and its regulator spends most of its life cold; a prime power set runs continuously and its regulator spends its life at operating temperature. The KCR760 is rated for -40 to +60 degC, which is fine in both cases provided the terminal box has any ventilation at all. What changes between the two duties is the capacitor ageing inside the board, not the semiconductor, so a prime power machine should have the regulator inspected on a schedule rather than on failure.

Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.

Paralleling setup. With two sets on the bus, adjust droop until reactive load divides in proportion to machine rating, then check it again at half load. A droop setting that looks right at full load and wrong at half load is usually a CT ratio error rather than a regulator fault.

The field resistance check. Measure the exciter field with the regulator disconnected and the machine stopped, then measure again after a run. Cold resistance is what the board sees at start-up; hot resistance is what it sees at full load. The KCR760 is specified with a minimum of Matched to the exciter field, and the real question is not whether the measured value is above that figure but whether the forcing current at that resistance still reaches the level the alternator needs to recover from a load step.

Spares strategy. Keep one regulator of each family in stock rather than several of one. A failed AVR takes a set off line in seconds and the replacement lead time is measured in days, which is why the cost of the spare is trivial compared with the cost of the outage.

Documentation. Insist on the wiring drawing for the exact suffix being supplied. Generic family drawings are the reason installations end up with the sensing on the wrong tap, and the resulting fault is indistinguishable from a faulty board.

Standby versus prime power. A standby set runs a few hundred hours a year and its regulator spends most of its life cold; a prime power set runs continuously and its regulator spends its life at operating temperature. The KCR760 is rated for -40 to +60 degC, which is fine in both cases provided the terminal box has any ventilation at all. What changes between the two duties is the capacitor ageing inside the board, not the semiconductor, so a prime power machine should have the regulator inspected on a schedule rather than on failure.

Wiring practice that prevents most call-backs. Run the sensing leads as a twisted pair, separate from the field cables, and land them on the terminals the drawing names rather than on the ones that happen to be nearest. On a KCR760 the sensing input draws very little current, which is exactly why it is vulnerable: a loose terminal adds resistance that the regulator reads as a voltage error and corrects by pushing the field up, so the machine runs hot and high for no visible reason.